Technical Specifications

C-3

1403-IN001A-US-P

General Input, Output, and Environmental
Ratings

Input and Output Ratings

Control Relay

Relay Life

General Specifications

Fiber Optic Cable Assembly Specifications

Control Power 1403-xMxxA

120V/240V AC 50/60 Hz or
125V/250V DC
(0.2 Amp maximum loading)

1403-xMxxB

24V AC 50/60 Hz or
24V/48V DC
(1 Amp maximum loading)

1403-DMA

120V/240V AC 50/60 Hz or
125V/250V DC
(0.05 Amp maximum loading)

1403-DMB

12V/24V AC 50/60 Hz or
12V/24V/48V DC
(0.15 Amp maximum loading)

Voltage Inputs Nominal Full Scale Input: 120V to 347V L-N

(208V to 600V L-L)
Input Impedance: 1 Meg-Ohm minimum

Current Inputs Nominal Full Scale Input:

0 to 1 Amp (1403-xM01x)
0 to 5 Amps (1403-xM05x)
Overload Withstand:
15 Amps Continuous,
300 Amps for one second
Burden: 0.05 VA
Impedance: 0.002 Ohms

Status Inputs

Contact Closure (Internal 24V DC)

Analog Input

Nominal Input: 1.0V AC/

±

1.4V DC

Overload Withstand: 120V for one minute

Rating

50/60 Hz AC rms

DC

Maximum Resistive
Load Switching

10A at 250V
(2500VA)

10A at 30V and
0.25A at 250V

Minimum Load
Switching

10mA at 24V

10mA at 24V

UL 508, CSA 22.2,
IEC Rating Class

B300

Q300

Maximum Make
Values (Inductive
Load)

30A at 120V
15A at 240V
(3600VA)

0.55A at 125V
0.27A at 250V
(69VA)

Maximum Break
Values (Inductive
Load)

3A at 120V
1.5A at 240V
(360VA)

0.55A at 125V
0.27A at 250V
(69VA)

Maximum Motor Load
Switching

1/3 HP at 125V
1/2 HP at 250V

Parameter

Number of Operations

Mechanical

5 X 10

6

Electrical

1 X 10

5

Dielectric
Withstand

Control Power

1600 Volts (Cat. No.
1403-MMxxA, -DMA)
500 Volts (Cat. No. 1403-
MMxxB, -DMB)

Voltage Inputs

2200 Volts

Current Inputs

4160 Volts

Status Inputs

1000 Volts

Control Relays

1600 Volts

Terminal Block
(+75

°

C Cu

wire only)

1403-xM Voltage
and Current
Terminals

10 AWG (6 mm

2

) max.,

16 lb-in (1.81 Nm) Torque

1403-xM Power,
Status, Analog,
Relay, and Ground
Terminals

12 AWG (4 mm

2

) max.,

(8 lb-in (0.90 Nm) Torque

1403-NSC
Terminals

14 AWG (2.5 mm

2

)

max.,5 lb-in (0.56 Nm)
Torque

1403-DM Terminals 14 AWG (2.5 mm

2

)

max.,5 lb-in (0.56 Nm)
Torque

Operating
Temperature

-40

°

C to +60

°

C (-40

°

F to +140

°

F)

Cat. No. 1403-MM, -NSC
-20

°

C to +60

°

C (-4

°

F to +140

°

F)

Cat. No. 1403-DM

Storage
Temperature

-40

°

C to +85

°

C (-40

°

F to +185

°

F)

Humidity

5% to 95%, Non-condensing

Vibration

10 to 500 Hz: 1G Operational (

±

0.006 in.) and

2.5G Non-operational (

±

0.015 in.)

Shock

1/2 Sine Pulse, 11 ms duration: 15G
Operational and 30G Non-operational

Parameter

Minimum

Maximum

Cable Length:
Distance
between two
adjacent
devices

25 cm (approx. 10 in.) shortest
Allen-Bradley standard

500 m
(1650 ft.)

Minimum
inside bend
radius

25.4mm (1 in.) Any bends with a
shorter inside radius can
permanently damage the fiber
optic cable. Signal attentuation
increases with decreased inside
bend radii.

N/A