Filter, Fnactive – Rockwell Automation 1398-PDM-xxx IQ Master Version 3.2.4 for IA-2000 and IQ-5000 Positioning Drive Modules, IQ-55 User Manual

Page 230

Advertising
background image

208

Language Reference • Reference

Publication 1398-PM601A-EN-P — October 2000

WORDS

FILTER

Velocity Loop Filter

Gain

Purpose

Set the current command filter. FILTER is the bandwidth in hertz (Hz) of the low pass
filter on the output of the velocity regulator (the current command). Reducing the
value of FILTER will smooth the current command which reduces noise from high fre-
quency current pulsation.

Syntax

FILTER = value
variable =
FILTER

value

The low pass filter roll off frequency in hertz (Hz). The maxi-
mum value is 300 Hz. Value can be a constant, a nonvolatile
variable Gn, a volatile variable Vn, or a system variable.

variable

The variable may be a nonvolatile variable Gn, a volatile vari-
able Vn, or a system variable.

Remarks

Changes made to this variable by a program are only in effect while the program is
running. When the program ends it will return to the value stored in the Personality
Module. If no change is made to this variable by the program, the value in the Person-
ality Module is used. The value in the Personality Module is set in the Parameter
menu, Gains/Limits dialog

See Also

Example

FILTER = 100

;set low pass filter roll off to 100Hz

FNACTIVE

Fkey active Flag

System

Purpose

Fkey pressed flag.

Syntax

variable = FNACTIVE

variable

If TRUE it indicates that an Fkey is pressed on the operator ter-
minal. Variable may be a nonvolatile flag Bn, a volatile flag Fn,
or another system flag.

Remarks

The flag is ON when an Fkey is pressed and OFF otherwise. A common use for this
flag is to permit something to happen as long as the Fkey is pressed.

See Also

XNACTIVE

Example

B2 = FNACTIVE

IF FNACTIVE = ON JOGF = ON ELSE JOGF = OFF

Advertising