;Expansion I/O - Not used

p;Expansion memory - Not used

;

;----------------------Scanned Events-----------------------

S1: IF I1=OFF state=2 ;looks for reverse limit

S2: IF I2=OFF state=3 ;looks for forward limit

S3: IF HSWSTAT=ON state=4 ;look for Home Switch active

S4: IF HSWSTAT=OFF state=8 ;look for Home Switch not active

S5: IF I1=I2 state=1 ;used during move off limit switch

;----------------------Begin Program -----------------------

;Variable Initialization

Start:

ALL OFF

limcnt = 0 ;set number of limit switches seen so far to 0.

HomeVel = HVEL ;set HomeVel (which will change) to HVel to start

origJacc = JACCEL ;save original Jog accel

origJdec = JDECEL ;save original Jog decel

JACCEL = ACCEL ;set home accel to default accel

JDECEL = ACCEL ;set home decel to default accel

creep = TBASE / SCALE ;Compute creep speed = 1 cnt / 2 ms.

IF INDEXEN=ON creep=creep*20 ;if doing index home, speed up creep

;limit all speeds to HomeVel

IF HomeVel>0 IF creep>HomeVel creep=HomeVel

IF HomeVel<0 IF creep>-HomeVel creep= -HomeVel

;If not already on the home switch or a limit switch,

;assume that home switch is in direction of the home

;velocity sign from the present position and move

;until limit switch or home switch is hit.

FOUNDHOME = OFF

IF HSWEN=ON JMP init01 ;check for Home Switch not defined

;if here, index home only.

;Make sure in same direction as HomeVel

IF HomeVel < 0 creep = -creep

IF INDEXEN=ON JMP jonsw0

;if should look for index, do it

JMP finish

;no index, no home switch,

; call where we are "home"

;if on switch, start in (-) direction

init01: IF HSWSTAT=ON IF HomeVel>0 HomeVel = -HomeVel

;if FAC, start out negative dir

IF I1=OFF IF HomeVel>0 HomeVel = -HomeVel

;if RAC, start out positive dir

IF I2=OFF IF HomeVel<0 HomeVel = -HomeVel

state=0

;skip limit checks if not enabled

IF HLimits=OFF JMP init02

IF I1=ON S1 CONT ELSE limcnt = limcnt+1;look for FAC

IF I2=ON S2 CONT ELSE limcnt = limcnt+1;look for RAC

;if both limit switches, error

IF limcnt=2 JMP err

init02: IF HomeVel>0 JMP fwrd