OVERSPEED
Overspeed Threshold
System
Purpose
Peak velocity trip point in user units per timebase. If the velocity exceeds this trip
point, a fault is reported.
Syntax
OVERSPEED = variable
variable = OVERSPEED
variable
Variable can be a constant, a nonvolatile variable Gn, a volatile
variable Vn, or another system variable.
Remarks
Changes made to this variable by a program are only in effect while the program is
running. When the program ends it will return to the value stored in the Personality
Module. If no change is made to this variable by the program, the value in the Person-
ality Module is used. The value in the Personality Module is set in the Parameter
menu, Velocity/Accel dialog box
See Also
VEL
Example
V4 = OVERSPEED
OVERSPEED=3500