Changes to version 3.0 from version 2.1, Changes to version 2.1 from version 2.xx, Changes to version 2.0 from version 1.xx – Rockwell Automation 1398-PDM-xxx IQ Master Version 3.2.4 for IA-2000 and IQ-5000 Positioning Drive Modules, IQ-55 User Manual

Page 433

Advertising
background image

What’s New in Each Version • New Features

411

Publication 1398-PM601A-EN-P — October 2000

APPENDIXES

Changes to Version 3.0 from Version 2.1

Support for IQ Cam

Tracking function enhancement to electronic gearing

Compiler options program statements

Off-line parameter editing

DDE Server capability

Support for redefining key codes for generic operator terminals

Support for connecting one Operator Terminal to multiple IQs

Movecomplete and Jogactive system flags

Toolbar button for File Transfer

Changes to Version 2.1 from Version 2.xx

Support for the IQ-550 Position Control Module

Support for a generic operator terminal

Default File Extension changes - all IQ files begin with “Q”

Toolbar buttons

Context Sensitive Help

Replace function added to the editor

Ability to monitor G and V variables

Ability to directly save a file to the IQ after successful compile

Changes to Version 2.0 from Version 1.xx

Multiple statements may be on one line:

START: V1=2.5 G1=V1*3.1 X3 CONT MD=G13 JUMP MAIN

Statements may be continued on multiple lines:

IF F1 = ON

G1 = POS2 ELSE G1 = POS1

Multiple statements may be treated as a group when contained in curly braces:

IF F1=ON {O1=ON G1=POS2}

Multiple statements in curly braces can also be used in scanned events:

S1: IF F1=ON {O2=ON G1=POS2 F2=OFF}

Two new programming statements have been added:

DO statement WHILE condition example: DO V1=V1+1 WHILE I12=ON
WHILE condition statements example: WHILE I12=ON {V1=V1+1 G3=V1+2}

Two additional variables have been added for positions captured on occurrence of an index pulse:
IX1P2 (POS2 on index 1) and IX2P1 (POS1 on index 2).

V1 = IX1P2

G2 = IX2P1

The ERETPOS variable for the emergency return position parameter may now also be called
EPOS.

V1 = ERETPOS

G2 = EPOS

Two variables have been added to allow setting the present jog acceleration and jog deceleration
parameters without changing the nonvolatile parameter values:

Advertising