Message formats appendix a – Rockwell Automation 1775-KA PLC-3 Communication Adapter Module User Manual User Manual

Page 165

Advertising
background image

Message Formats

Appendix A

AĆ3

Figure A.1

Cabling for a RS-232-C Line Monitor

1
2

3

4

5

6

7

8
20

25

25 Pin, Female

RS-232-C Connector

25 Pin, Male

RS-232-C Connector

25 Pin, Male

RS-232-C Connector

of 1775-KA

1775-KA

Toggle Switch

Connections

Channel B

Industrial Terminal

(Cat. No. 1770-T4)

To RS-232-C Device

2 = Transmit Data

3 = Receive Data

7 = Ground

18 = Received Data Return

25 = Transmitted Data Return

= Connect these lines according

to the specifications for your

modem or RS-232-C device.

3

7

18

25

10069-I

Advertising