Message Formats

Appendix A

AĆ20

Where the extended status byte is optional.

A PLC–3 receives privileged commands from an RS–232–C device (such
as a computer); the PLC–3 does not send these commands. The
privileged commands are:

privileged read

download request

privileged write

upload request

diagnostic counters reset

restart request

diagnostic loop

set ENQs

diagnostic read

set NAKs

diagnostic status

set timeout

Privileged Read

Use this read command with a PLC–3 physical address as a starting
address. You use this command to upload from a PLC–3 to a computer.
The destination 1775–KA module will accept this command only after the
source station has successfully transmitted a shutdown request. The
function code for this command is 9.

Command Format:

DLE

SRC

C

0

S

TNS

MD

F

TS

TNS

STX

FNC

09

SIZE

DST

DLE ETX

BCC

PLC-3

physical address

Reply Format:

TDATA–Max of 238 bytes or 119 words DLE ETX BCChis is the same
as the reply packet format for all reads.

A. Format when the command was successfully executed

DLE

C

S

TNS

MD TS

TNS

STX

DLE ETX

BCC

DATA - Max of 244 bytes or 122 words

DST SRC

4F

B. Format when reporting an error

DLE

SRC

STX

DST

C

4F

S

TNS

MD

TS

TNS

DLE ETX

BCC

ETX

STS

Where the extended status byte is optional.

Privileged Commands