Data Highway Communication

Chapter 3

3Ć3

To enter a message instruction, complete the steps below:

1.

Enter a condition that, when true, will activate the message
instruction. In Figure 3.1, we used an examine–on for input word
0012

8

, bit 01.

Figure 3.1

Levels of Programming in Data Highway Communication

STAT

MSG

MESSAGE TYPE 1

STAT

10012

01

STAT

CTL = FB200:0000=200

CHANNEL: E2.5.1

EN

12

DN

15

ER

13

2) 1775–KA Module

@PROC_A

Data Highway Message Procedure

PROC_A

#H024$B12:37 = 15

Message procedure command

to transmit a message to data

highway station number 24

Message instruction to

execute message procedure

PROC_A

1) PLC–3 Processor

Ladder Diagram Program

3) Data Highway

DLE

STX

DST

SRC CMD

STS

TNSW

ADDR

SIZE

DATA

DLE

EXT

BCC

(OPTIONAL)

Command message

transmitted to

station 24

10014–I