Rockwell Automation 1746-HSCE,D17466.5 High-Speed Counter Module User Manual
Page 175

Publication 1746-UM006B-EN-P - August 2005
Sequencer Mode Configuration Worksheets E-5
Output Status and Configuration Error Code (page 4-43)
Next Sequencer Step and Current Sequencer Step (page 4-44)
Next Sequencer Step Preset (decimal) (page 4-45)
Module Setup Information
Module ID Code = 12705 (8 Input and 1 Output word)
File Size - 42 word integer file, and 42 word M0 File
I:e.4
7
6
5
4
3
2
1
0
Bit Number (decimal)
15
14
13
12
11
10
9
8
Output Number
7
6
5
4
3
2
1
0
Output Status and Configuration Error Code
0000 = no error
0001 = not defined
0010 = Max Count equals 0 (ring)
0011 = Invalid Operating Mode
0100 = Invalid Input Type
0101 = Static Parameter Changed
0110 = Ranges Active equals 0
0111 = Rate Period equals 0
1000 = Linear Counter Reset Value out of range
1001 = Sequencer Preset > Maximum Count
Configuration Error Code
R R
R R
0 = output OFF
1 = output ON
Output Status
Outputs 0 thru 3 relate to Physical Outputs
Outputs 4 thru 7 relate to Soft Outputs
I:e.5
7
6
5
4
3
2
1
0
Bit Number (decimal)
15
14
13
12
11
10
9
8
Next Sequencer Step
Current Sequencer Step
I:e.7
Next Sequencer Step Preset