Abort index decel, Index 0 type, Index 0 distance/ position – Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual

Page 106: Index 0 count

Advertising
background image

Publication 2098-RM001C-EN-P – August 2002

2-90

Programming Reference

352

Get

Index Status

WORD

2

Returns the status of an index move.
Bit 0 = Start Index Execution
Bit 1 = Start New Index Execution
Bit 2 = Index Run - In Accel or Constant Velocity
Bit 3 = In Decel
Bit 4 = In Dwell
Bit 5 = Move Adjusted by Registration
Bit 6 = End of Batch Count
Bit 7 = Negative Distance Index
Bit 8 = Registration Input Seen
Bit 9 = Not Homed - Absolute index started before
homing
Bit 10 = Aborting Index - Index is being aborted,
initiated from a digital input
Bit 11 = Blended to Index - Previous index ended
with a nonzero velocity
Bit 12 = Reversing Direction
Bit 13 = Sensor Unassigned - Registration index with
no sensor assigned
Bit 14 = Overtravel Limit - Index is being aborted,
initiated from an overtravel limit

353

Get

Selected Index

USINT

1

The selected index.
Range: 0 to 63

354

Get

Index Count

UINT

The number of iterations remaining in the execution
of the index.
Range: 0 to 65535

355

Set

Auto-Start Index

USINT

1

Determines if the drive will begin executing the
selected index whenever the drive is enabled.
0 - Disable (default)
1 - Enable

356

Set

Abort Index
Decel

UDINT

4

Cnts /
Sec

2

The deceleration rate used to stop motion when the
Abort (Stop) input terminates an index move.
Range: 0 to 0x7fffffff
Default: 100000

357
and
367, 377, …,
967, 977, 987

Set

Index 0 Type

and
Index n Type
where n = 1-63

USINT

1

Selects the type of index move.
0 - Incremental (default)
1 - Absolute
2 - Registration
3 - Jog

358
and
368, 378, …,
968, 978, 988

Set

Index 0 Distance/
Position

and
Index n
Distance/Position
where n = 1-63

DINT

4

Cnts

For Incremental and Registration index moves,
specifies the relative distance of travel. For Absolute
moves, specifies the final position of the index
move. For a Jog index move, specifies the maximum
distance of travel.
Range: -0x7fffffff to 0x7fffffff
Default: 1000

359
and
369, 379, …,
969, 979, 989

Set

Index 0 Count

and
Index n Count
where n = 1-63

UINT

2

The number of times the index move will execute. If
it is set to zero (0), the index move will be executed
continuously.
Range: 0 to 65535
Default: 1

Parameter Object,
Instances ID = 1- 996

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description