271

Set

Motor Gear
Count 3

INT

2

Cnts

Motor encoder counts for preset gear ratio 3. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count. This
value should be nonzero.
Range: -32767 to 32767
Default: 1

272

Set

Master Gear
Count 4

UINT

2

Cnts

Master encoder counts for preset gear ratio 4. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count.
Range: 1 to 32767
Default: 1

273

Set

Motor Gear
Count 4

INT

2

Cnts

Motor encoder counts for preset gear ratio 4. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count. This
value should be nonzero.
Range: -32767 to 32767
Default: 1

274

Set

Master Gear
Count 5

UINT

2

Cnts

Master encoder counts for preset gear ratio 5. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count.
Range: 1 to 32767
Default: 1

275

Set

Motor Gear
Count 5

INT

2

Cnts

Motor encoder counts for preset gear ratio 5. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count. This
value should be nonzero.
Range: -32767 to 32767
Default: 1

276

Set

Master Gear
Count 6

UINT

2

Cnts

Master encoder counts for preset gear ratio 6. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count.
Range: 1 to 32767
Default: 1

277

Set

Motor Gear
Count 6

INT

2

Cnts

Motor encoder counts for preset gear ratio 6. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count. This
value should be nonzero.
Range: -32767 to 32767
Default: 1

278

Set

Master Gear
Count 7

UINT

2

Cnts

Master encoder counts for preset gear ratio 7. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count.
Range: 1 to 32767
Default: 1

279

Set

Motor Gear
Count 7

INT

2

Cnts

Motor encoder counts for preset gear ratio 7. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count. This
value should be nonzero.
Range: -32767 to 32767
Default: 1