Slew enable, Slew limit, Master gear count 0 – Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual

Page 98: Motor gear count 0, Master gear count 1, Motor gear count 1, Master gear count 2, Motor gear count 2, Master gear count 3

Advertising
background image

Publication 2098-RM001C-EN-P – August 2002

2-82

Programming Reference

261

Set

Analog Decel
Limit

UDINT

4

Cnts /
Sec

2

The deceleration limit used when the drive is in
Analog Velocity Input mode and Parameter 259,
Limit Analog Accel is set to 1 - Enable.
Range: 0 to 0x7fffffff
Default: 100000

262

Set

Slew Enable

USINT

1

Used to enable or disable the Gear Slew Rate.
0 - Disable (default)
1 - Enable

263

Set

Slew Limit

UDINT

4

Cnts /
Sec

2

Slew rate (acceleration/deceleration limit) used for
gearing.
Range: 0 to 0x7fffffff
Default: 100000

264

Set

Master Gear
Count 0

UINT

2

Cnts

Master encoder counts for preset gear ratio 0. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count.
Range: 1 to 32767
Default: 1

265

Set

Motor Gear
Count 0

INT

2

Cnts

Motor encoder counts for preset gear ratio 0. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count. This
value should be nonzero.
Range: -32767 to 32767
Default: 1

266

Set

Master Gear
Count 1

UINT

2

Cnts

Master encoder counts for preset gear ratio 1. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count.
Range: 1 to 32767
Default: 1

267

Set

Motor Gear
Count 1

INT

2

Cnts

Motor encoder counts for preset gear ratio 1. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count. This
value should be nonzero.
Range: -32767 to 32767
Default: 1

268

Set

Master Gear
Count 2

UINT

2

Cnts

Master encoder counts for preset gear ratio 2. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count.
Range: 1 to 32767
Default: 1

269

Set

Motor Gear
Count 2

INT

2

Cnts

Motor encoder counts for preset gear ratio 2. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count. This
value should be nonzero.
Range: -32767 to 32767
Default: 1

270

Set

Master Gear
Count 3

UINT

2

Cnts

Master encoder counts for preset gear ratio 3. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count.
Range: 1 to 32767
Default: 1

Parameter Object,
Instances ID = 1- 996

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description