Feedback data value – Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual
Page 52

Publication 2098-RM001C-EN-P – August 2002
2-36
Programming Reference
Assembly Object,
Instance ID = 16 - Input Assembly
Feedback Data Value
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Feedback Data Value - Low Byte
1
Feedback Data Value - Low Middle Byte
2
Feedback Data Value - High Middle Byte
3
Feedback Data Value - High Byte
Assembly Object,
Instance ID = 17 - Input Assembly
Extra Status Byte (with Write Data Status bits, Handshake Echo Bit, and Feedback Data Pointer) and Feedback Data Value
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Write Data
Busy/Ack
Write Data
Error
Reserved
Feedback Data Pointer
1
Feedback Data Value - Low Byte
2
Feedback Data Value - Low Middle Byte
3
Feedback Data Value - High Middle Byte
4
Feedback Data Value - High Byte
Assembly Object,
Instance ID = 18 - Input Assembly
Extra Status Byte with Write Data Status Bits, and Handshake Echo Bit
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Write Data
Busy/Ack
Write Data
Error
Reserved
Reserved
Reserved
Reserved
Reserved