Index 0 dwell, Index 0 registration distance, Index 0 velocity – Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual

Page 107: Index 0 accel, Index 0 decel, Index 0 pointer, Index 0 terminate

Advertising
background image

Publication 2098-RM001C-EN-P – August 2002

Programming Reference

2-91

360

and
370, 380, …,
970, 980, 990

Set

Index 0 Dwell

and
Index n Dwell
where n = 1-63

UINT

2

mSec

The amount of time the drive holds position before
continuing to the next index.
Range: 0 to 65535
Default: 0

361

and
371, 381, …,
971, 981, 991

Set

Index 0
Registration
Distance

and
Index n
Registration
Distance
where n = 1-63

UDINT

4

Cnts

For Registration index moves, specifies the relative
distance of travel after a registration digital input is
detected.
Range: 0 to 0x7fffffff
Default: 1000

362

and
372, 382, …,
972, 982,
992

Set

Index 0 Velocity

and
Index n Velocity
where n = 1-63

UDINT

4

Cnts /
Sec

The commanded velocity used when executing the
index.
Range: 0 to 0x7fffffff
Default: 100000

363

and
373, 383, …,
973, 983,
993

Set

Index 0 Accel

and
Index n Accel
where n = 1-63

UDINT

4

Cnts /
Sec

2

The acceleration rate used to change to higher
velocity during the index move.
Range: 0 to 0x7fffffff
Default: 100000

364

and
374, 384, …,
974, 984,
994

Set

Index 0 Decel

and
Index n Decel
where n = 1-63

UDINT

4

Cnts /
Sec

2

The deceleration rate used to change to a lower
velocity during the index move.
Range: 0 to 0x7fffffff
Default: 100000

365

and
375, 385, …,
975, 976,
995

Set

Index 0 Pointer

and
Index n Pointer
where n = 1-63

USINT

1

Specifies the next index move to execute if the Index
0 Terminate parameter is not set to 'Stop'.
Range: 0 to 63
Default: 0

366

and
376, 386, …,
976, 986,
996

Set

Index 0 Terminate

and
Index n Terminate
where n = 1-63

USINT

1

The drive's action when the index move has
completed.
0 - Stop
1 - Start Next Index immediately
2 - Wait for Start - 'Start Index' active transition
required to start next index.
3 - Index Without Stop - execute the next index
without stopping. The dwell time is ignored and a
'Start Index' is not required.

Parameter Object,
Instances ID = 1- 996

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description