2-17
Assembly Object,
Instance ID = 7 - Output Assembly
32 Bit Logic Command
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Reserved
Reserved
Reserved
Abort Homing Pause
Homing
Abort
Indexing
Pause Index
Disable Serial
1
Reserved
Reserved
Preset Select
5
Preset Select
4
Preset Select
3
Preset Select
2
Preset Select
1
Preset Select
0
2
Reserved
Position
Strobe
Operation
Mode
Override
Reserved
Reserved
Follower
Enable
Integrator
Inhibit
Define
Position
3
Enable
Reset Faults
Start Homing
Remove
Offset
Reserved
Define Home
Start Index
Reset Drive
Assembly Object,
Instance ID = 8 - Output Assembly
32 Bit Logic Command, Handshake Bit, and Feedback Data Pointer
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Reserved
Reserved
Reserved
Abort Homing Pause
Homing
Abort
Indexing
Pause Index
Disable Serial
1
Reserved
Reserved
Preset Select
5
Preset Select
4
Preset Select
3
Preset Select
2
Preset Select
1
Preset Select
0
2
Reserved
Position
Strobe
Operation
Mode
Override
Reserved
Reserved
Follower
Enable
Integrator
Inhibit
Define
Position
3
Enable
Reset Faults
Start Homing
Remove
Offset
Reserved
Define Home
Start Index
Reset Drive
4
Reserved
Reserved
Handshake
Reserved
Feedback Data Pointer