System Troubleshooting

This chapter describes the most common operating problems, the
probable causes, and recommended corrective actions including:

troubleshooting procedure

troubleshooting checklists

boot-up error messages

general error and information messages

The RAC6181 Computer is equipped with a red LED indicator (

) on

the front panel that indicates when the unit has exceeded the defined
thresholds for operation. When this LED indicator is lit, the RAC6181
Computer has exceeded one of the following threshold settings:

Voltage ranges

Temperature requirements

Chassis fan speed

You need to perform the following procedure to determine which
thresholds have been exceeded.

1. Shutdown the RAC6181 Computer using the appropriate method for

your operating system.

2. Apply power to the RAC6181 Computer.

3. Press and hold the F2 key after the memory check is completed to

enter BIOS Setup.

The BIOS Setup Menu is displayed.

4. Press the right arrow key to select the Hardware menu.

5. Press the down arrow key to select each hardware submenu and

press Enter. Check the Current value for each setting against the
specified threshold to determine if the setting has exceeded the
threshold.