To install the RAC6181 Computer in a panel using mounting clips:

ATTENTION: Disconnect all electrical power from the
panel before making cutout.

Make sure the area around the panel cutout is clear.

Take precautions so that metal cuttings do not enter any
components that are already installed in the panel.

Failure to follow these warnings may result in personal
injury or damage to the panel components.

To install the RAC6181 Computer in a panel using mounting clips:

1. Cut an opening in the panel using the appropriate panel cutout

dimensions provided on 2-11.

2. Make sure the RAC6181 Computer sealing gasket is properly

positioned on the terminal. This gasket forms a compression type
seal, do not use sealing compounds.

3. Place the RAC6181 Computer in the panel cutout.

4. Install the mounting clips. The mounting clips slide into the six slots

on the top and bottom of the RAC6181 Computer.

Mounting