9–6

Replacing the Backlight Tubes

Publication 6181-UM001D-EN-P

5. Pivot the chassis to the left. If you have a touchscreen unit, make

sure the touchscreen cable comes out of the chassis without
becoming snagged and damaged.

6. Lift and pivot the chassis off of the display assembly and place the

chassis on its side to the left of the display assembly.

7. Disconnect the display cable from the flat panel display by removing

the 2 screws holding it to the small printed circuit board on the
display (see figure below). The display assembly is now completely
free of the unit.

Replacing the backlight tubes:

1. Remove the 2 screws holding each backlight tube in place.

Backlight Screws

Display Cable
Retaining
Screws

Backlight Screws

Backlight
Retaining Tabs

Backlights
are shaded
in gray.

2. Slide the tube to the right about 1/8 in. (3 mm) and gently pull the

tube up and out of the assembly.

3. Insert the replacement backlight tube into the slot and slide it to the

left until the holes for the screws are aligned.