3-14 Make Cable Connections

You must cut or heat shrink the drain wire when you use round

5-wire (thin) drop cable.

Install end caps

Each KwikLink terminator module is supplied with an end cap designed to
cover the exposed end of the cable. To install the end cap:

1. Fit the end cap (1485A-CAP) on the cable as keyed. Align the end cap

posts with the receptacles in the lower IDC base and press down until
the end cap is firmly seated (the upper surface of the posts will be flush
with the upper surface of the base).

2. Close the IDC base and continue with the connection process as

illustrated on page 3-10.

IMPORTANT

When installing an end cap on the other end of the cable,
note that the guide receptacles are on the upper portion of
the IDC base.

41809

red

white

blue

black

red

white

blue

black

The round 4-wire
KwikLink drop cable
(gray) has no drain wire.

To use round 5-wire (thin) drop
cable, bend back and heat shrink,
or cut, the drain wire.

Use only with
KwikLink

Wire
Color

Wire
identity

Use

Flat

white

CAN_H

signal

signal

blue

CAN_L

signal

signal

bare

drain

shield

n/a

black

V-

power

power

red

V+

power

power

Align the end cap posts with
receptacles in the base.