b. If using thread type connectors, leave the o-ring in place.

c. Align flats on each connector.

Do not apply excessive force when mating the cable and motor
connectors. If the connectors do not go together with light hand force,
realign and try again For the quick-connect connector, push the
connector on and apply a quarter turn.

ATTENTION: Remove the o-ring when using a quick-connect
connector. The o-ring will block the locking mechanism, rendering
it ineffective.

A threaded connector will fit on the male connector with or without
the o-ring. If the o-ring is not used on a threaded connector, the
connection will eventually vibrate loose.

3

1

2

4

6

5

To User Supplied Encoder

To Drive

Item

Description

1

Power connector

2

Feedback connector

3

Encoder connector

4

Connect your encoder using Encoder Connector Kit, catalog
number LDC-ENC-CNCT

5

Feedback Extension Cable, catalog number 2090-CFB7DF-CDAFxx or 2090-
XXNFMF-Sxx

6

Power Extension Cable, catalog number 2090-CPWM7DF-xxAFxx or 2090-
XXNPMF-xxSxx