Wire the LDC-Series Linear Motor Chapter 5

Cables Exit in the Center

If mounting coils in tandem, such that the power cables exit in the center as
shown, use the following table to find the mounting distance and the phase
wiring.

Figure 4 - Mounting Two Coils with Cables Exit in the Center

Coil #1

Coil #2

Coil #1 is the master.

Hall Effect
Module

L

Table 6 - Phase Wiring for Center-exit Power Cables

L
mm (in.)

Coil # 1
Master

(1)

Coil # 2
Slave

(2)

Amplifier
Phase

133.33 (5.249)

Red

Black

U

White

White

V

Black

Red

W

(1) Master has Hall effect module.
(2) Slave has no Hall effect module.