Cables exit on opposite ends – Rockwell Automation LDC Iron Core Linear Servo Motors User Manual

Page 44

Advertising
background image

44

Rockwell Automation Publication LDC-UM001B-EN-P - March 2011

Chapter 5 Wire the LDC-Series Linear Motor

Cables Exit on Opposite Ends

If mounting coils in tandem such that the power cables exit opposite to each other
as shown, use the following table to find the mounting distance and the phase
wiring.

Figure 5 - Mounting Two Coils with Cables Exit on Opposite Ends

Coil #1

Coil #2

Coil #1 is the master.

Hall Effect
Module

L

Table 7 - Phase Wiring for Opposite End-exit Power Cables

L
mm (in.)

Coil # 1
Master

(1)

Coil # 2
Slave

(2)

Amplifier
Phase

100.00 (3.94)

Red

Red

U

White

Black

V

Black

White

W

133.33 (5.249)

Red

Black

U

White

White

V

Black

Red

W

(1) Master has Hall effect module.
(2) Slave has no Hall effect module.

Advertising