Rockwell Automation LDC Iron Core Linear Servo Motors User Manual
Page 50
Advertising
![background image](/manuals/581161/50/background.png)
50
Rockwell Automation Publication LDC-UM001B-EN-P - March 2011
Chapter 6 Configure and Start Up the LDC-Series Linear Motor
5.
Using the screen image as a reference, configure the parameters as shown in
the Setting column.
Figure 7 - RSLogix 5000 Software, Version 15.00 and 16.00, TTL Encoder
Figure 8 - RSLogix 5000 Software, Version 15.00 and 16.00, Sin/Cos Encoder
Parameter
Setting
Comment
Feedback Type
TTL or Sin/Cos
For RSLogix 5000 software,
version 16
TTL with Hall or Sin/Cos with Hall
For RSLogix 5000 software,
version 17
Cycles
50
5 µm encoder
125
2 µm encoder
250
1 µm encoder
500
0.5 µm encoder
2500
0.1 µm encoder
50
20 µm Sin/Cos encoder
25
40 µm Sin/Cos encoder
per
Millimeters
–
Interpolation Factor
4
TTL
1024
Sin/Cos
Advertising