Cooling plate flow rate specifications – Rockwell Automation LDC Iron Core Linear Servo Motors User Manual
Page 70

70
Rockwell Automation Publication LDC-UM001B-EN-P - March 2011
Appendix A Specifications and Dimensions
Cooling Plate Flow Rate Specifications
Cat. No.
Coil
Cat. No.
Cooling Plate
Air Flow Rate
(1)
L/min (ft
3
/hr)
(1) These are the flow rates required to maintain air pressure at 0.689 bar (10 lb/in.
2
).
Water Flow Rate
(3)
bar (psi)
(3) These are the flow rates required to maintain water pressure at 3.8 L/min (1 gal/min).
LDC-C030100-xxxxx
LDC-030-100-CP
N/A
(2)
(2) This flow rate is not available. Call Application Engineering (631-344-6600) for assistance.
N/A
(2)
LDC-C030200-xxxxx
LDC-030-200-CP
N/A
(2)
N/A
(2)
LDC-C050100-xxxxx
LDC-050-100-CP
N/A
(2)
0.41 (6)
LDC-C050200-xxxxx
LDC-050-200-CP
N/A
(2)
0.48 (7)
LDC-C050300-xxxxx
LDC-050-300-CP
N/A
(2)
0.55 (8)
LDC-C075200-xxxxx
LDC-075-200-CP
N/A
(2)
0.48 (7)
LDC-C075300-xxxxx
LDC-075-300-CP
N/A
(2)
0.55 (8)
LDC-C075400-xxxxx
LDC-075-400-CP
N/A
(2)
0.69 (10)
LDC-C100300-xxxxx
LDC-100-300-CP
61.4 (130)
0.69 (10)
LDC-C100400-xxxxx
LDC-100-400-CP
N/A
(2)
0.83 (12)
LDC-C100600-xxxxx
LDC-100-600-CP
47.2 (100)
0.97 (14)
LDC-C150400-xxxxx
LDC-150-400-CP
N/A
(2)
0.83 (12)
(4)
(4) These are the flow rates required to maintain water pressure at 7.57 L/min (2 gal/min).
LDC-C150600-xxxxx
LDC-150-600-CP
N/A
(2)
0.93 (13.5)
(4)