Cooling plate flow rate specifications – Rockwell Automation LDC Iron Core Linear Servo Motors User Manual

Page 70

Advertising
background image

70

Rockwell Automation Publication LDC-UM001B-EN-P - March 2011

Appendix A Specifications and Dimensions

Cooling Plate Flow Rate Specifications

Cat. No.
Coil

Cat. No.
Cooling Plate

Air Flow Rate

(1)

L/min (ft

3

/hr)

(1) These are the flow rates required to maintain air pressure at 0.689 bar (10 lb/in.

2

).

Water Flow Rate

(3)

bar (psi)

(3) These are the flow rates required to maintain water pressure at 3.8 L/min (1 gal/min).

LDC-C030100-xxxxx

LDC-030-100-CP

N/A

(2)

(2) This flow rate is not available. Call Application Engineering (631-344-6600) for assistance.

N/A

(2)

LDC-C030200-xxxxx

LDC-030-200-CP

N/A

(2)

N/A

(2)

LDC-C050100-xxxxx

LDC-050-100-CP

N/A

(2)

0.41 (6)

LDC-C050200-xxxxx

LDC-050-200-CP

N/A

(2)

0.48 (7)

LDC-C050300-xxxxx

LDC-050-300-CP

N/A

(2)

0.55 (8)

LDC-C075200-xxxxx

LDC-075-200-CP

N/A

(2)

0.48 (7)

LDC-C075300-xxxxx

LDC-075-300-CP

N/A

(2)

0.55 (8)

LDC-C075400-xxxxx

LDC-075-400-CP

N/A

(2)

0.69 (10)

LDC-C100300-xxxxx

LDC-100-300-CP

61.4 (130)

0.69 (10)

LDC-C100400-xxxxx

LDC-100-400-CP

N/A

(2)

0.83 (12)

LDC-C100600-xxxxx

LDC-100-600-CP

47.2 (100)

0.97 (14)

LDC-C150400-xxxxx

LDC-150-400-CP

N/A

(2)

0.83 (12)

(4)

(4) These are the flow rates required to maintain water pressure at 7.57 L/min (2 gal/min).

LDC-C150600-xxxxx

LDC-150-600-CP

N/A

(2)

0.93 (13.5)

(4)

Advertising