3 rsć232 communication port, 4 option board connector, 5 operator interface module connector – Rockwell Automation GV3000 AC Pwr Module Ver. 5.0 Hardware Ref, Installation, and Troubleshooting User Manual

Page 31: 6 keypad/display

Advertising
background image

2Ć15

2.7.3 RSĆ232 Communication Port

The Regulator board contains a 9Ćpin DĆshell RSĆ232 communication port (J8). This port provides

RSĆ232 communication between the GV3000 drive and a personal computer running the Control and

Configuration (CS3000) software. See figures 2.8 and 2.9. Refer to instruction manual D2Ć3348, for

more information.

2.7.4 Option Board Connector

The flatĆribbon cable connector (J3) on the left side of the Regulator board is a parallel bus

connection port that provides a means of attaching optional boards such as the DeviceNet board, the

RMI board, or the AutoMax Network Communication board to the GV3000 drive. See figures 2.8

and 2.9. The option board is mounted below the Regulator board inside the drive. Refer to the

appropriate board instruction manual for more information. Refer to section 2.7 of this manual for

more information on optional drive kits.

2.7.5 Operator Interface Module Connector

FlatĆribbon connector J7 provides a means of attaching the optional Operator Interface module

(OIM). The OIM is available for use as a remote keypad for the GV3000.

2.7.6 Keypad/Display

The front panel keypad/display is used to program and operate the GV3000 drive. See figure 2.13.

Refer to instruction manual D2Ć3339 for more information.

1. When this LED is on, parameters cannot be modified

from the keypad without entering the correct password

into P.051 (Programming Disable).

1. Stops the drive.

2. Resets faults.

1. Applies power to the motor if the

keypad is selected as the control source.

Figure 2.13 Ć Keypad/Display

Advertising