Appendix A

Equipment Phase Instructions (PSC, PCMD, POVR, PFL, PCLF, PXRQ, PRNP, PPD, PATT, PDET)

Equipment Phase Clear
Failure (PCLF)

Use the PCLF instruction to clear the failure code of an equipment phase.

Operands:

Relay Ladder

Structured Text

The operands are the same as those for the relay ladder PCLF instruction.

Description:

The PCLF instruction clears the failure code for an equipment phase.

• You must use a PCLF instruction to clear the failure code of an

equipment phase.

• A CLR instruction, MOV instruction, or assignment (:=) doesn’t change

the failure code of an equipment phase.

• Make sure the equipment phase doesn’t have other owners when you

use the PCLF instruction. The PCLF instruction won’t clear the failure
code if RSLogix 5000 software, FactoryTalk Batch software, or another
program owns the equipment phase.

Arithmetic Status Flags:

not affected

Fault Conditions:

none

Operand

Type

Format

Description

Phase Name

phase

name of the
equipment
phase

Equipment phase whose failure code you
want to clear