Create a PanelView Plus Application
In this chapter, you learn how to complete the following tasks:
•
Create a push button and a multi-state indicator in FactoryTalk View Studio software.
•
Transfer the application to the 2711P-K10C4D1 drive so you can test communication with
the controller.
Before You Begin
You must complete these tasks before using this chapter:
•
The tasks described in
Before Using This Publication on page 5
, including:
–
Prepare the Logix5000 control system hardware
–
–
- The tasks described in this chapter require an
EtherNet/IP network.
–
Create an RSLogix 5000 project
- In your RSLogix 5000 project, include a ladder logic
rung with Examine On and Output Energize elements as shown. In this example, the
alias tag named OB16_Light is an alias for point Local:1:O.Data.0.
The example RSLogix 5000 project used in this chapter uses a
CompactLogix 5370 L3 controller.