SECTION 5: MAINTENANCE

5.01 General Maintenance

Perform the following checks periodically to ensure proper system performance.

Power Supply Maintenance Schedule

Daily

Check coolant level; add coolant as needed.

Check gas hose connections and pressures.

UC-AC Maintenance schedule

Monthly

Check cooling fan and radiator; clean as needed.

Check gas hoses for cracks, leaks, or abrasion.

Replace as needed.

Check all electrical connections

for cracks or abrasion. Replace as needed.

Six Months

Clean or replace external coolant filter.

Clean coolant tank.

Vacuum out any dust buildup inside power supply.

5.02 External Coolant Filter Cleaning Procedure

Periodic cleaning of the coolant filter ensures maximum coolant flow efficiency. Poor coolant flow causes inefficient

torch parts cooling with consequent faster consumable wear.

Clean the coolant filter as follows:

1. Disconnect system from main input power.

2. Unscrew and remove the filter canister by hand. Large canister located at the back of the power supply. Be

sure to keep the O-ring.

3. Inspect and replace filter as needed. Re-install the canister, tightening it by hand. Be sure the O-ring is in

place.

�. Turn the system on and check for leaks.