ULTRA-CUT 100 XT

3-22

INSTALLATION

Manual 0-5303

3. Attach all hoses and cables to the front of the DMC-3000 except the Fiber Optic cable which will be covered

a little later. Avoid turning any fittings already mounted in the unit by placing a wrench on it before tightening

the hose fitting to it.

Art # A-09141_AB

NOTE

Argon must be used for the “Marking” gas. If replacing existing fittings in the base, apply thread sealant

to the fitting threads, according to manufacturer’s instructions. Do not use Teflon tape as a thread sealer,

as small particles of the tape may break off and block the small air passages in the torch.

NOTE

If you need to replace a gas or water fitting all inlets and outlets of the aluminum manifold are 1/4” NPT

(United States National Pipe Thread) into which are screwed the various adapters.

4. Connect the ground cable to rear of DMC-3000 shown in previous illustration.
5. Connect Control cable from the Power Supply to J56 on the front of the DMC-3000 as shown below. The

Fiber Optic cable will be covered a little later.

Art # A-09142_AB