Ultra-cut 100 xt – Tweco 100 Ultra-Cut Plasma Cutting System with Automated Gas Control User Manual

Page 171

Advertising
background image

ULTRA-CUT 100 XT

Manual 0-5303

APPENDIX

A-47

Status codes.

The codes for the power supply are displayed on the Display PCB 4 digit numerical display. Some codes refer to

the Gas Controls but more detailed Gas Control codes will be found on the individual gas controls. The gas con-

trols used with the XT family of plasma supplies have not changed. They have their own set of status codes which

should be covered in another section. This guide assumes you have first considered the Status Code Tables in the

Operation Section of the unit manual. Individual codes will point to different inverter sections while this guide groups

similar codes together. For example code E (or L) 249 indicates an inverter fault in Inverter 2A. This guide covers

codes 247-252 in one section as they are all the same, varying only by which inverter and section they refer to.

The codes are separated into � groups.

Group 1

Plasma Process -- Relating to pilot, transfer, torch voltages, etc.

Group 2

Plasma Power Supply -- Primarily the Inverter Sections

Group 3

Interface to Gas controls -- Mainly the DFC 3000

Group 4

Cooling System -- The liquid cooling system for the torch and inverters

Group 5

CCM -- Communications port to the gas controls

For the XT units we are using a 3 digit code with group 1 codes in the 100’s, group 2 in the 200s etc. These cor-

respond to the older codes used in previous units, where 1-1 is now 101. For the most part the codes have the

same meaning. Where an older code no longer applies to the XT system we don’t use it over again and have left

it reserved to avoid confusion. For example the code 204 (2-4) which meant the inverter module wasn’t ready. We

now detect that error in a different way that has a somewhat different meaning so we have reserved the 204 Code.
While most of the codes indicate a fault has occurred, a few of them, such as 304 (formerly 3-4), simply refer to the

current status. 304 indicates either “priming” where the pump is filling the system with coolant or more often “purg-

ing” where the gas is flowing to dry the consumables after replacing them or purging the gas lines when a different

gas type has been selected.

Troubleshooting (General)

In many cases where the cause may be listed as a cable or wire disconnected but also includes loose or broken.
All Ribbon cables have an extra receptacle near one end for measuring signals on the cable.
A number of the measurements will require probing of some small connectors or measuring signal on ribbon cables.

For probing the small connectors, standard meter probes are usually too big. We suggest making a couple probes

using steel wire. Copper buss wire isn’t stiff enough. A paper clip is a little too big. One idea is take a socket from

an Amp mate-n-loc or similar connector into which your meter probe will fit and crimp a small piece of steel wire,

(0.020 to 0.025” dia.; (0.5-0.6 mm) works best), into where wire would normally be crimped. The wire should be

soldered and crimped. The steel wire may be found in hobby stores that cater to model building.

Art # 12302

Art # 12303

Insulate all but the end of the wire and slide these onto your meter probe. If your meter has alligator clip adaptors

you could hold the wire in these as well, be sure they don’t short together.

Problems that do not set Status or Fault codes:

1. At power on GAS LED blinks continuously, no code set. Real problem is no or low coolant flow but it takes

4 minutes before code is set and people don’t wait that long.