Ultra-cut 100 xt – Tweco 100 Ultra-Cut Plasma Cutting System with Automated Gas Control User Manual

Page 92

Advertising
background image

ULTRA-CUT 100 XT

�-22

OPERATION

Manual 0-5303

CCM Status Code

Group 3 -- Gas Controller Status & Protocol

Code

Message

Remedy / Comments

301

Gas control communication

fault

Problem with fiber optic cable to GCM 2010 or DMC or DPC; Dirt on fiber ends

or in connectors; blow out with clean dry air. Fiber not locked into connector;

Sharp bends in fiber cable; Fiber defective; GCM 2010 circuit board defect;

DMC or DPC power supply defective; DMC or DPC circuit board defect

302

Gas Control reply fault

Problem with fiber optic cable to GCM 2010 or DMC or DPC; Dirt on fiber ends

or in connectors; blow out with clean dry air. Fiber not locked into connector;

Sharp bends in fiber cable; Fiber defective; GCM 2010 circuit board defect;

DMC or DPC power supply defective; DMC or DPC circuit board defect

303

Gas Supply Pressure out of

range.

GCM 2010 inlet plasma or shield pressure low or defective pressure sensors

PS3 & PS4; Defective GCM 2010 PCB; For DFC 3000 see DPC for pressure

faults.

304

Gas Control Purging

Normal following power up or returning from Plasma Disable. Wait for purge

to finish.

305

Gas Control protocol error

Verify Firmware revision for compatibility with GCM 2010 or DMC and DPC

306

Not used

Reserved for other future use.

307

Gas Control sequencing

error

Verify Firmware revision for compatibility with GCM 2010 or DMC and DPC

308

Gas Control Type Mismatch

Wrong CCM (Auto-Cut or Pak 200 type?) for Ultra-Cut; Install correct CCM

309

Gas Control command fault

Verify Firmware revision for compatibility with GCM 2010 or DMC and DPC;

Electromagnetic interference with Arc Starter; inspect grounding; bonding; and

isolation

310 *

DPC fault

Check DPC status indicator for specific problem

311 *

DPC valve controlling fault Check DPC status indicator for specific problem

312 *

DMC fault

Check DMC status indicator for specific problem

313 *

Gas Controller not config-

ured.

DMC or DPC not configured for a process or locked; See DMC and DPC status

* Applies to DFC 3000 (Auto Gas) only