05 lift the power supply, Lift the power supply -4, Ultra-cut 100 xt – Tweco 100 Ultra-Cut Plasma Cutting System with Automated Gas Control User Manual
Page 28

ULTRA-CUT 100 XT
3-�
INSTALLATION
Manual 0-5303
3.05 Lift the Power Supply
WARNINGS
Do not touch live electrical parts.
Disconnect input power conductors from de-energized supply line before moving unit.
FALLING EQUIPMENT can cause serious personal injury and equipment damage.
Use a forklift, crane, or hoist to lift the unit off the shipping pallet as shown. Keep the power supply steady and verti-
cal. Do not lift it any further than necessary to clear the shipping pallet. Ensure all panels and screws are secure
prior to lifting.
Art # A-11531_AC
Set the power supply on a solid, level surface. The installer may fasten the power supply to the floor or a support-
ing fixture with hardware passing through the horizontal parts of the power supply feet.