ULTRA-CUT 100 XT

�-20

OPERATION

Manual 0-5303

242

Inverter 1B Input Volt-

age Error

Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of In-

verter Module 1 Section B; Poor AC Power Quality; Defective W1 contactor; Loose or

open connection between input terminals and W1 contactor or contactor and input

of Inverter Section; Defective Inverter module

243

Inverter 2A Input Volt-

age Error

Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of In-

verter Module 2 Section A; Poor AC Power Quality; Defective W1 contactor; Loose or

open connection between input terminals and W1 contactor or contactor and input

of Inverter Section; Defective Inverter module

244

Inverter 2B Input Volt-

age Error

Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of In-

verter Module 2 Section B; Poor AC Power Quality; Defective W2 contactor; Loose or

open connection between input terminals and W2 contactor or contactor and input

of Inverter Section; Defective Inverter module

245

Inverter 3A Input Volt-

age Error

Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of In-

verter Module 3 Section A; Poor AC Power Quality; Defective W2 contactor; Loose or

open connection between input terminals and W2 contactor or contactor and input

of Inverter Section; Defective Inverter module

246

Inverter 3B Input Volt-

age Error

Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of In-

verter Module 3 Section B; Poor AC Power Quality; Defective W2 contactor; Loose or

open connection between input terminals and W2 contactor or contactor and input

of Inverter Section; Defective Inverter module

247

Inverter 1A Circuit

Fault

Inverter Module 1 Section A detected a circuit fault; Damaged Inverter Module 1

248

Inverter 1B Circuit

Fault

Inverter Module 1 Section B detected a circuit fault; Damaged Inverter Module 1

249

Inverter 2A Circuit

Fault

Inverter Module 2 Section A detected a circuit fault; Damaged Inverter Module 2

250

Inverter 2B Circuit

Fault

Inverter Module 2 Section B detected a circuit fault; Damaged Inverter Module 2

251

Inverter 3A Circuit

Fault

Inverter Module 3 Section A detected a circuit fault; Damaged Inverter Module 3

252

Inverter 3B Circuit

Fault

Inverter Module 3 Section B detected a circuit fault; Damaged Inverter Module 3

253

Inverter 1A Over Temp

Inverter Module 1 Section A is over temperature; Operating with side panels re-

moved, Check for restricted air flow, clogged radiator; Defective fan; If problem

persists replace inverter module.

254

Inverter 1B Over Temp

Inverter Module 1 Section B is over temperature; Operating with side panels re-

moved, Check for restricted air flow, clogged radiator; Defective fan; If problem

persists replace inverter module.

255

Inverter 2A Over Temp

Inverter Module 2 Section A is over temperature; Operating with side panels re-

moved, Check for restricted air flow, clogged radiator; Defective fan; If problem

persists replace inverter module.

256

Inverter 2B Over Temp

Inverter Module 2 Section B is over temperature; Operating with side panels re-

moved, Check for restricted air flow, clogged radiator; Defective fan; If problem

persists replace inverter module.

257

Inverter 3A Over Temp

Inverter Module 3 Section A is over temperature; Operating with side panels re-

moved, Check for restricted air flow, clogged radiator; Defective fan; If problem

persists replace inverter module.

258

Inverter 3B Over Temp

Inverter Module 3 Section B is over temperature; Operating with side panels re-

moved, Check for restricted air flow, clogged radiator; Defective fan; If problem

persists replace inverter module.