ULTRA-CUT 100 XT

3-20

INSTALLATION

Manual 0-5303

NOTE

There are holes added in the rear panel for customer wiring. This, rather than the one in the CCM will be

the preferred place for customer added wiring (and strain relief) for connections to height controls, etc..

3.15 DMC-3000 Gas Manifold Control Installation

The DMC-3000 Gas Control must be installed in a suitable location where it is easily accessible to the system op-
erator. The unit must be mounted to a flat horizontal surface. If the Module is mounted to any support subject to
vibration or motion, the installer must fasten the module to the support securely.

The Module should be located as far away as possible from the Arc Starter due to possible electromagnetic inter-
ference. It is acceptable to locate the control cable in the same track as the cables from the Arc Starter and away
from torch leads.

The Module includes feet which lift the bottom panel of the mounting surface. Louvers on the back panel of the
module must remain unblocked, for the free passage of ventilating air.

Mounting Dimensions

5.00 in

[127.0 mm]

7.08 in

[179.8 mm]

12.18 in

[309.4 mm]

11.44 in

[290.6 mm]

.30 in

[7.62 mm]

DMC-3000 Top

13.60 in

[345.6 mm]

DMC-3000 Profile

Art # A-09459