Ultra-cut 100 xt – Tweco 100 Ultra-Cut Plasma Cutting System with Automated Gas Control User Manual

Page 65

Advertising
background image

ULTRA-CUT 100 XT

Manual 0-5303

INSTALLATION

3-�1

4. Insert the stack of consumable parts into the cartridge. Ensure that the large O-ring on the torch tip fits

completely into the cartridge. If any part of the O-ring protrudes from the cartridge, the parts are not seated
properly.

5. Use the cartridge tool to hold the cartridge assembly, while turning the shield cup (and shield retainer for

200 Amp parts) onto the cartridge assembly. For 300 Amp parts turn the shield retainer onto the shield cup
now. When this group is fully assembled, the shield should protrude from the front of the shield cup or shield
retainer. Without this protrusion the shield cup is not properly tightened onto the cartridge assembly.

6. Take the cartridge tool off the cartridge. Fit the cartridge assembly onto the torch head. The Speed Lok

ring should click into place and the cartridge assembly should touch the large O-ring on the torch body.

Torch Head O-Ring

Torch Head

Art # A-08300_AB

0.063 - 0.083"

(1.6 - 2.1 mm)

Protrusion

Installing Assembled Cartridge Onto Torch Head

7. Slide the ohmic clip over the shield cup if using ohmic torch height sensing.
8. Connect the wire lead from the height finder to the ohmic clip if using ohmic torch height sensing.

Ohmic Clip

Art # A-03393_AB

NOTE

Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically

with the ohmic sensing circuit.

Advertising