Ultra-cut 100 xt – Tweco 100 Ultra-Cut Plasma Cutting System with Automated Gas Control User Manual

Page 53

Advertising
background image

ULTRA-CUT 100 XT

Manual 0-5303

INSTALLATION

3-29

3.18 Fiber Optic Cable Installation From DMC-3000 to DPC-3000

1.

Remove outer thin nuts from through hole protector at both ends of Fiber Optic Cable (L) that connects

between the DCM-3000 and DPC-3000.

CAUTION

Avoid kinking, twisting, or bunching the fiber optic cable. The cable can be damaged by being forced
into tight-radius turns.

2. Ensure that the outer protective hose/cable is exposed beyond the through hole protector approximately

1” and secure by tightening the wide nut with the rounded end while holding the other nut in place. Normal

hand tightening is not enough.

3. Feed the Fiber Optic Cable plug and wires through the back of each module (DMC-DPC) where indicated

and slide the thin nut back over the Fiber Optic Cable.

Fiber Optic for

DMC-3000 goes here

Art # A-09152_AB

Insert Fiber Optic cable here

Art # A-09153_AB