3.16 DPC-3000 Gas Pressure Control Installation

The DPC-3000 Gas Control must be installed in a suitable location close to the Torch such as the gantry. The unit
must be mounted to a flat horizontal surface. If the Module is mounted to any support subject to vibration or motion,
the installer must fasten the module to the support securely.

The Module should be located as far away as possible from the Arc Starter due to possible electromagnetic inter-
ference. It is acceptable to locate the control cable in the same track as the cables from the Arc Starter and away
from torch leads.

The Module includes feet which lift the bottom panel off the mounting surface. Louvers on the back panel of the
module must remain unblocked, for the free passage of ventilating air.

The Module also comes with non metallic isolation grommets for mounting. These must be used in all four mount-
ing slots to raise the Module so there is no metal to metal contact between the Module and the mounting surface
in order to reduce the chance of EMI interference.

Mounting Dimensions

10.90 in

[276.86 mm]

DPC-3000 Profile

4.00 in

[101.6 mm]

6.64in

[168.7mm]

11.00 in

[279.4 mm]

10.45 in

[265.4 mm]

.30 in

[7.62mm]

DPC-3000 Top

Art # A-09143