INSTALLATION

3-19

2 - Wire and 4 - Wire settings

When used with the TSC-3000 the plug should be in the 2 wire (2W) position shown below.

For other CNC controls using � wire communication such as the XT iCNC, place the jumper in the �W position.

Art # 12322

3.14 Height Control Connections

The terminal strip provides connections to negative Arc Volts (Torch or electrode), Tip Volts (Pilot) and Work.

These are for a height control that requires connection to the full non-divided arc voltage. Also available on the

terminal strip are 120VAC and 2� VAC. The allowable current draw is 100ma @ 120VAC and 1Amp @ 2� VAC.

Art # A-11900

24 VAC

@ 1A

TB4

1

2

3

4

5

6

7

120 VAC

@ 100 ma.

Work

Tip Volts

(Pilot)

Arc Volts

(Torch)

Art # A-11954