12 dmc-3000 status codes, Dmc-3000 status codes -24, Ultra-cut 100 xt – Tweco 100 Ultra-Cut Plasma Cutting System with Automated Gas Control User Manual

Page 94

Advertising
background image

ULTRA-CUT 100 XT

�-2�

OPERATION

Manual 0-5303

CCM Status Code

Group 6 -- CCM

Code

Message

Remedy / Comments

601

Analog Voltage Error

Defective CCM, replace.

602

ADC or DAC error

Defective CCM, replace.

603

Reserved

No information available; Contact customer service

604

Data Memory error

Defective CCM, replace.

605

Program memory fault

Defective CCM, replace.

606

+5V Logic supply low

Defective CCM, replace.

607

Processor over temperature

Reduce ambient temperature; Defective CCM; replace

608

5V supply for RS 485/422 com-

munication low.

Defective CCM, replace.

609

Firmware Update Device Error

Defective CCM; replace

610

Firmware Update Protocol Error Defective CCM; replace

611

USB Controller Fault

Defective CCM; replace

612

USB Power Fault

Faulty USB device plugged into USB port, remove; Defective CCM

613

USB Log Creation Fault

Unable to create Log file on USB Flash drive last firmware update at-

tempt; Use different USB Flash Drive or Reformat

614

No USF File

File VTCCMFW.USF missing from Flash Drive; Add proper files to Flash

Drive for Firmware Update; Use different USB Flash Drive or Reformat

615

No CCM Update File

CCM Firmware file specified in VTCCMFW.USF not found ; Add proper

files to Flash Drive for Firmware updating

616

DPC Update Fault

Fault occurred attempting to update DPC firmware; Add proper files to

USB Flash drive for Firmware updating; Refer to CCM_LOG.TXT on Flash

Drive for details

617

DMC Update Fault

Fault occurred attempting to update DMC firmware; Add proper files to

USB Flash drive for Firmware updating; Refer to CCM_LOG.TXT on Flash

Drive for details

618

ADC Calibration Fault

Error too large calibrating ADC; Fault persists defective CCM;

619

Flow Switch Fault

Flow switch reporting coolant flow when pump off;

620

Non Volatile Memory Error

Non Volatile Memory Storage Corrupted and Erased; Fault persists

defective CCM.

4.12 DMC-3000 Status Codes

Status Code indicators:

1. At power up, RED & GREEN indicators flash program firmware revision number in a 2 digit code as ex-

plained below. Following the revision code

2. Green indicator

· On steady = OK, communication established.
· Blinking = no communication established with CCM
3. Red indicator

· Off = Status OK
· Rapid blinking = downloading new program
· Blinking 2 digit code = Status (table below)

Advertising