Ultra-cut 100 xt – Tweco 100 Ultra-Cut Plasma Cutting System with Automated Gas Control User Manual

Page 89

Advertising
background image

ULTRA-CUT 100 XT

Manual 0-5303

OPERATION

�-19

222

Inverter 3A Output

Current High

Plasma work current high during cutting and attributed to Inverter Module 3 Section

A output high; If problem persists replace Inverter Module 3

223

Inverter 3B Output

Current High

Plasma work current high during cutting and attributed to Inverter Module 3 Section

B output high; If problem persists replace Inverter Module 3

224

Inverter 1 Not Found Inverter Module 1 Section A required for Piloting; Bad ribbon cable connection to

CCM J31 to Inverter Module 1 Section A.

225

Inverter 1A Incompat-

ible Revision

Unsupported Inverter Revision; Ribbon cable CCM J31 to Inverter Module 1 Section

A damaged; CCM code version incompatible with Inverter revision or model

226

Inverter 1B Incompat-

ible Revision

Unsupported Inverter Revision; Ribbon cable CCM J32 to Inverter Module 1 Section

B damaged ; CCM code version incompatible with Inverter revision or model

227

Inverter 2A Incompat-

ible Revision

Unsupported Inverter Revision; Ribbon cable CCM J33 to Inverter Module 2 Section

A damaged; CCM code version incompatible with Inverter revision or model

228

Inverter 2B Incompat-

ible Revision

Unsupported Inverter Revision; Ribbon cable CCM J34 to Inverter Module 2 Section

B damaged; CCM code version incompatible with Inverter revision or model

229

Inverter 3A Incompat-

ible Revision

Unsupported Inverter Revision; Ribbon cable CCM J35 to Inverter Module 3 Section

A damaged; CCM code version incompatible with Inverter revision or model

230

Inverter 3B Incompat-

ible Revision

Unsupported Inverter Revision; Ribbon cable CCM J36 to Inverter Module 3 Section

B damaged; CCM code version incompatible with Inverter revision or model

231

Inverter 1A VAC

Mismatch

Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad

ribbon cable connection CCM J31 to Inverter Module 1 Section A; Wrong voltage

Inverter Module 1 installed; Defective Inverter module

232

Inverter 1B VAC

Mismatch

Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad

ribbon cable connection CCM J32 to Inverter Module 1 Section B; Wrong voltage

Inverter Module 1 installed; Defective Inverter module

233

Inverter 2A VAC

Mismatch

Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad

ribbon cable connection CCM J33 to Inverter Module 2 Section A; Wrong voltage

Inverter Module 2 installed; Defective Inverter module

234

Inverter 2B VAC

Mismatch

Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad

ribbon cable connection CCM J34 to Inverter Module 2 Section B; Wrong voltage

Inverter Module 2 installed; Defective Inverter module

235

Inverter 3A VAC

Mismatch

Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad

ribbon cable connection CCM J35 to Inverter Module 3 Section A; Wrong voltage

Inverter Module 3 installed; Defective Inverter module

236

Inverter 3B VAC

Mismatch

Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad

ribbon cable connection CCM J36 to Inverter Module 3 Section B; Wrong voltage

Inverter Module 3 installed; Defective Inverter module

237

Too Few Inverters

Found

Two or more Inverter Sections required to operate; Ribbon cable from CCM to

Inverter Section damaged or disconnected;

238

BIAS VAC Invalid

Invalid AC Voltage Selection; Damaged or loose connection at J61 of System Bias

Supply; Defective System Bias PCB

239

AC Voltage High

System Bias PCB detected AC Voltage is higher than Power Supply rated Voltage;

System Bias Supply J61 Voltage Selection connection damaged or disconnected;

Defective System Bias PCB; Defective CCM

240

AC Voltage Low

System Bias PCB detected AC Voltage is lower than Power Supply rated Voltage;

System Bias Supply J61 Voltage Selection connection damaged or disconnected;

Defective System Bias PCB; Defective CCM

241

Inverter 1A Input Volt-

age Error

Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of In-

verter Module 1 Section A; Poor AC Power Quality; Defective W1 contactor; Loose or

open connection between input terminals and W1 contactor or contactor and input

of Inverter Section; Defective Inverter module

Advertising