Dismount hoppers, Disconnect sensors and chain, Disconnect level sensors – Great Plains 2007HD Update Installation User Manual
Page 17: Dismount rate sensor, Dismount final drive chain, Dismount hoppers disconnect sensors and chain
05/25/2011
166-370M
Great Plains Manufacturing, Inc.
13
Dismount Hoppers
Hoppers and their mount, are removed to:
• provide clearance to install new hopper braces;
• protect the hoppers from welding damage; and,
• ease update of meter supports.
The hoppers must be empty.
Supports are required. If an original export shipping rack
is available, it would be ideal. Otherwise, provide two
wide or four narrow supports of equal height, at least
33 cm (13 in.) in height.
Disconnect Sensors and Chain
Disconnect Level Sensors
Refer to Figure 17
55. At each hopper, disconnect the hopper level sensor
lead
from the air cart harness
.
Dismount Rate Sensor
Refer to Figure 18
56. At the left end of each meter box, disconnect the
sensor’s anti-rotation strap ( , not visible in Figure),
from the sensor mount
.
57. Cut the cable tie
.
58. Loosen the thumbscrew
.
Swing away the rate sensor
.
Re-tighten the thumbscrew to prevent loss.
59. Remove and save two pins:
805-155C PIN WIRE RETAIN 5/16 X 2 1/2
60. Remove and save both gears:
168-243D GEAR 54 TOOTH QUICK CHANGE
808-192C GEAR 17 TOOTH QUICK CHANGE
Dismount Final Drive Chain
Refer to Figure 19
61. At the right end of each meter, loosen the final drive
idlers
. Lift the chain
off the meter input
gear
. It is not necessary to remove the chain
entirely. The sprocket is left installed.
Figure 17
Hopper Level Sensor Lead
Q0101
151
146
Figure 18
Rate Sensor
31373
198
198
145
162
204
130
157
2
139
146
151
2
162
157
162
145
198
130
204
Figure 19
Final Drive Chain
Q0033
129
221
102
221
102
129