Close-Out

382. Remove all part number tags, grease-pencil and

paint-pencil part numbers.

383. If a suitable tractor and field are available, test all

hydraulic functions. Also perform some passes to
confirm coulter to row alignment.

Reconfigure Monitor

The DICKEY-john

®

IntelliAg

®

WSMT is still programmed

with the prior bus configuration of this air drill. When first
powered-up after the update, the monitor is likely to dis-
play an alarm when it discovers the new WSMB. Even
without an alarm, the sensor to row assignments are
incorrect.

These instructions presume that the monitor already has
Materials and Channels defined.

The steps below require a password to enter User
Level 2. Consult the IntelliAg

®

ACC manual (

110011512

).

384. Set the Master Switch off.

385. Power up the monitor (turn on tractor ignition).

386. If a configuration error is detected (virtually certain

on the first power-up), press the Alarm Cancel
(CANCEL) softkey.

387. Press NEXT PAGE softkey until the MODULE CFG

softkey appears.

388. Press the MODULE CFG softkey.

389. Press the AUTO CONFIG softkey.

390. Press the AUTO SORT softkey.

391. Move the WSMT-ACCGP to MODULE ADDR 1.

392. Press the ROW ASSIGN softkey. Verify that the row

assignments are as shown in the table at right. See
ACC manual for how to re-order assignments.

393. Press the CTRL SETUP softkey.

Note: Consult the factory on the next steps. A monitor

firmware update was pending when this manual
was initially released, and the exact softkey se-
quences were not yet documented.

This completes the update.

Figure 106

Monitor Console

25421

WSMB

ID

a

a. This is the hand-applied number from Enumerate

WSMBs” on page 42.

MODULE

# OF

ROWS

ROW

#’s

ADDR.

Type

1

Note

b

b. These numbers are not shown, as they vary

depending on POM and the serial numbers of
WSMB modules not used for material rate sensing.

WSMB-18R

12

1-12

2

Note

b

WSMB-18R

16

13-28

3

Note

b

WSMB-18R

12

29-40

4

Note

b

WSMB-18R

12

41-52

5

Note

b

WSMB-18R

16

53-68

6

Note

b

WSMB-18R

12

69-80