Power distribution board, Removing the power distribution board – Dell PowerEdge R415 User Manual

Page 142

Advertising
background image

142

Installing System Components

3 Slide the backplane downward until the two blue retention latches snap

into place.

4 Connect the SAS data and power cables to the SAS backplane.
5 Reconnect the power cable to the control panel board. See Figure 3-29.
6 Install the hard drives in their original locations.
7 Close the system. See "Closing the System" on page 83.

Power Distribution Board

The power distribution board is located on your system directly behind the

power supply fan modules. This feature provides additional cooling to the

power supplies through the power distribution shroud that routes airflow to

the power supplies. See Figure 3-31.

Removing the Power Distribution Board

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in
your product documentation, or as directed by the online or telephone service
and support team. Damage due to servicing that is not authorized by Dell is
not covered by your warranty. Read and follow the safety instructions that
came with the product.

1 Remove the power supplies from the system. See "Removing a Redundant

Power Supply" on page 95.

2 Locate the power distribution shroud and lift it out. See Figure 3-1.
3 Disconnect power distribution cables from the system board (see "System

Board" on page 144) and disconnect the fan cable connectors. See Figure 3-31.

4 Remove the two screws securing the power distribution board to the

chassis. See Figure 3-31.

5 Slide the power distribution board away from the standoffs, and then lift

the board out. See Figure 3-31.