Dell PowerEdge R415 User Manual
Page 51

About Your System
51
Unsupported
memory
configuration.
DIMM mismatch
across slots
detected:
x,x,...
Invalid memory
configuration. Memory
modules are mismatched in
the specified slots.
Ensure that the memory
modules are installed in a
valid configuration. See
Warning: A fatal
error has caused
system reset!
Please check the
system event log!
A fatal system error occurred
and caused the system to
reboot.
Check the SEL for
information that was logged
during the error. See the
applicable troubleshooting
section in "Troubleshooting
page 157 for any faulty
components specified in the
SEL.
Warning! Power
required exceeds
PSU wattage.
Check PSU and
system
configuration.
Warning!
Performance
degraded. CPU and
memory set to
minimum
frequencies to
meet PSU wattage.
System will
reboot.
The system configuration of
processor(s), memory
modules, and expansion
cards may not be supported
by the power supplies.
If any system components
were just upgraded, return
the system to the previous
configuration. If the system
boots without this warning,
then the replaced
component(s) are not
supported with this power
supply. If low wattage power
supplies are installed, replace
them with High Output
power supplies to use the
components. See "Power
Table 1-3. System Messages
(continued)
Message
Causes
Corrective Actions