Dell PowerEdge R415 User Manual

Page 51

Advertising
background image

About Your System

51

Unsupported
memory
configuration.
DIMM mismatch
across slots
detected:
x,x,...

Invalid memory

configuration. Memory

modules are mismatched in

the specified slots.

Ensure that the memory

modules are installed in a

valid configuration. See

"General Memory Module

Installation Guidelines" on

page 122.

Warning: A fatal
error has caused
system reset!
Please check the
system event log!

A fatal system error occurred

and caused the system to

reboot.

Check the SEL for

information that was logged

during the error. See the

applicable troubleshooting

section in "Troubleshooting

System Memory" on

page 157 for any faulty

components specified in the

SEL.

Warning! Power
required exceeds
PSU wattage.
Check PSU and
system
configuration.
Warning!
Performance
degraded. CPU and
memory set to
minimum
frequencies to
meet PSU wattage.
System will
reboot.

The system configuration of

processor(s), memory

modules, and expansion

cards may not be supported

by the power supplies.

If any system components

were just upgraded, return

the system to the previous

configuration. If the system

boots without this warning,

then the replaced

component(s) are not

supported with this power

supply. If low wattage power

supplies are installed, replace

them with High Output

power supplies to use the

components. See "Power

Supplies" on page 95.

Table 1-3. System Messages

(continued)

Message

Causes

Corrective Actions

R415HOM.book Page 51 Friday, September 24, 2010 9:37 AM