Dell PowerEdge R415 User Manual

Page 38

Advertising
background image

38

About Your System

E2112 Memory spared

on DIMM ##.
Power cycle
AC.

The system BIOS has

spared the memory

because it has determined

the memory had too many

errors. "##" represents the

memory module

implicated by the BIOS.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Troubleshooting

System Memory" on

page 157.

I1910 Intrusion

detected.
Check chassis
cover.

System cover has been

removed.

Information only.

I1912 SEL full.

Review & clear
log.

The SEL is full of events

and is unable to log any

more.

Check the SEL for details

on the events, then clear

the SEL.

I1920 iDRAC6 Upgrade

Successful

Optional iDRAC6 has

been upgraded

successfully.

W1228 RAID

Controller
battery
capacity <
24hr.

Warns predictively that

the RAID battery has

less than 24 hours of

charge left.

Allow RAID battery to

charge to greater than

24 hours of

sustained charge.
If problem persists,

replace RAID battery.

See "Installing the RAID

Battery" on page 121.

W1627 Power required

> PSU wattage.
Check PSU and
config.

The system configuration

requires more power than

what the power supply can

provide.

Turn off power to the

system, reduce the

hardware configuration or

install higher-wattage

power supplies, and then

restart the system.

Table 1-2. LCD Status Messages (Optional)

(continued)

Code

Text

Causes

Corrective Actions

R415HOM.book Page 38 Friday, September 24, 2010 9:37 AM