25
Table 1-2. LCD Status Messages (Optional)
Code
Text
Causes
Corrective Actions
E1000 Failsafe
voltage error.
Contact
support.
Check the system event
log for critical failure
events.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E1114 Ambient Temp
exceeds
allowed range.
Ambient temperature has
a reached a point outside
of the allowed range.
E1116 Memory
disabled, temp
above range.
Power cycle
AC.
Memory has exceeded
allowable temperature and
has been disabled to
prevent damage to the
components.
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting
If the problem persists,
E1119 Chipset # temp
out of range.
Check
motherboard
heatsinks.
Chipset temperature
reached a point outside
the allowed range.
E1210 Motherboard
battery
failure. Check
battery.
CMOS battery is missing
or the voltage is outside of
the allowable range.
E1211 RAID
Controller
battery
failure. Check
battery.
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Reseat the RAID battery
connector. See "RAID
R415HOM.book Page 25 Friday, September 24, 2010 9:37 AM