Installing a redundant power supply – Dell PowerEdge R415 User Manual

Page 96

Advertising
background image

96

Installing System Components

Figure 3-10. Removing and Installing a Redundant Power Supply

Installing a Redundant Power Supply

1 Verify that both power supplies are of the same type and have the same

maximum output power.

NOTE:

The maximum output power (shown in watts) is listed on the power

supply label.

2 If applicable, remove the power supply blank. See "Removing the Power

Supply Blank" on page 97.

3 Slide the new power supply into the chassis until the power supply is fully

seated and the release latch snaps into place. See Figure 3-10.

NOTE:

If you unlatched the cable management arm in step 1 of the previous

procedure, relatch it. For information about the cable management arm, see

the system’s rack documentation.

4 Connect the power cable to the power supply and plug the cable into a

power outlet.

CAUTION:

When connecting the power cable, secure the cable with the

Velcro strap.

1

power supply

2

locking tab

3

cable retention bracket

1

2

3

R415HOM.book Page 96 Friday, September 24, 2010 9:37 AM