Dell PowerEdge R415 User Manual

Page 28

Advertising
background image

28

About Your System

E1420 CPU Bus parity

error. Power
cycle AC.

The system BIOS has

reported a processor bus

parity error.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 181.

E1421 CPU #

initialization
error. Power
cycle AC.

The system BIOS reported

a processor initialization

error.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 181.

E1422 CPU # machine

check error.
Power
cycle AC.

The system BIOS has

reported a machine

check error.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 181.

E1610 Power Supply #

(### W)
missing.
Check power
supply.

Specified power supply

was removed or is missing

from the system.

See "Troubleshooting

Power Supplies" on

page 155.

E1614 Power Supply #

(### W) error.
Check power
supply.

Specified power supply

has failed.

See "Troubleshooting

Power Supplies" on

page 155.

E1618 Predictive

failure on
Power Supply #
(### W).
Check PSU.

An over-temperature

condition or power supply

communication error has

caused the predictive

warning of an impending

power supply failure.

See "Troubleshooting

Power Supplies" on

page 155.

Table 1-2. LCD Status Messages (Optional)

(continued)

Code

Text

Causes

Corrective Actions

R415HOM.book Page 28 Friday, September 24, 2010 9:37 AM

Advertising