Dell PowerEdge R415 User Manual

Page 49

Advertising
background image

About Your System

49

Time-of-day not
set - please run
SETUP program.

Incorrect Time or Date

settings; faulty system

battery.

Check the Time and Date

settings. See

"Using the

System Setup Program

and UEFI Boot Manager"

on page 57

. If the problem

persists, replace the system

battery. See "System Battery"

on page 133.

Timer chip
counter 2 failed.

Faulty system board.

See "Getting Help" on

page 181.

TPM or TCM
configuration
operation
honored. System
will now reset.

A Trusted Platform Module

(TPM) or China Trusted

Platform Module (TCM)

configuration command has

been entered. The system

will reboot and execute the

command.

Information only.

TPM or TCM
configuration
operation is
pending. Press
(I) to Ignore OR
(M) to Modify to
allow this change
and reset the
system.
WARNING:
Modifying could
prevent
security.

This message displays during

system restart after a TPM or

TCM configuration

command has been entered.

User interaction is required

to proceed.

Enter I or M to proceed.

TPM or TCM
failure.

A TPM or TCM function has

failed.

See "Getting Help" on

page 181.

Table 1-3. System Messages

(continued)

Message

Causes

Corrective Actions

R415HOM.book Page 49 Friday, September 24, 2010 9:37 AM