Dell PowerEdge R415 User Manual

Page 48

Advertising
background image

48

About Your System

SATA port x
device auto-
sensing error.
SATA port x
device
configuration
error.
SATA port 0
device failure.

The drive connected to the

specified SATA port is faulty.

Replace the faulty drive.

Requested sector
not found.
Seek error.
Seek operation
failed.

Faulty hard-drive, USB

device, or USB medium.

Replace the USB medium or

device. Ensure that the USB

or SAS backplane cables are

properly connected. See

"Troubleshooting a USB

Device" on page 150 or

"Troubleshooting a Hard

Drive" on page 163 for the

appropriate drive(s) installed

in your system.

Shutdown
failure.

General system error.

See "Getting Help" on

page 181.

The amount of
system memory has
changed.

Memory has been added or

removed or a memory

module may be faulty.

If memory has been added or

removed, this message is

informative and can be

ignored. If memory has not

been added or removed,

check the SEL to determine

if single-bit or multi-bit

errors were detected and

replace the faulty memory

module. See

"Troubleshooting System

Memory" on page 157.

Time-of-day
clock stopped.

Faulty battery or faulty chip. See "Troubleshooting the

System Battery" on page 155.

Table 1-3. System Messages

(continued)

Message

Causes

Corrective Actions

R415HOM.book Page 48 Friday, September 24, 2010 9:37 AM