About Your System
SATA port x
device auto-
sensing error.
SATA port x
device
configuration
error.
SATA port 0
device failure.
The drive connected to the
specified SATA port is faulty.
Replace the faulty drive.
Requested sector
not found.
Seek error.
Seek operation
failed.
Faulty hard-drive, USB
device, or USB medium.
Replace the USB medium or
device. Ensure that the USB
or SAS backplane cables are
properly connected. See
Drive" on page 163 for the
appropriate drive(s) installed
in your system.
Shutdown
failure.
General system error.
The amount of
system memory has
changed.
Memory has been added or
removed or a memory
module may be faulty.
If memory has been added or
removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to determine
if single-bit or multi-bit
errors were detected and
replace the faulty memory
module. See
Time-of-day
clock stopped.
Faulty battery or faulty chip. See "Troubleshooting the
Table 1-3. System Messages
(continued)
Message
Causes
Corrective Actions